DSCP81-02

Configurable Voltage/Current Input Signal Conditioner, DIN Mount

DSCP81-02
Configurable Voltage/Current Input Signal Conditioner, DIN Mount

Product Availability:
  • Usually stock to 2-3 weeks.

Description

Each isolated DSCP81 signal conditioner is designed for measuring voltages up to ±1000VDC and currents up to ±100mA. The input type, measurement range, and other features are software configurable. A PC with RS-232C serial port, the DSCX-787 and DSCX-587 interface cables, and the DSCX-557 configuration software are required to program the DSCP81.

The DSCP81 can interface to either a current or voltage input and provide a current or voltage output. The input filter characteristics, input and output ranges, input signal linearization, signal inversion, and optional alarm relay output are all software configurable by the user. The input signal may be linearized using up to 50 points of interpolation. Optionally, the user may specify all configurable parameters and request factory configuration.

Two models are available offering wide-range power supply connection: 24 to 60VDC/AC, and 85 to 230VDC/AC. The DSCX-557 configuration software allows query, print-out and saving of configuration settings, display of input measurement value, and display of interpolation table points.

Specifications

  • Input Type Voltage, Current
  • Output Type Voltage, Current
  • Mechanical Format DIN rail
  • Internal Power Supply None
  • Isolation Voltage 3700 Vrms
  • Isolation Type Transformer 3-way
  • Accuracy <±0.1%
  • Supply Voltage 85 to 230 VDC/AC
  • Input Voltage Withstand
  • Gain/Offset Adjust Programmable
  • Module Bandwidth Programmable
  • NMR (60 Hz) Rejection Programmable
  • External I-to-V Resistor N/A
  • Output Control Continuous
  • Load Resistance Rmin>=Output Voltage End Value/10mA
  • Dimensions 4.49 x 2.72 x 0.69 inches
  • Interface Miniature Screw Terminals
  • Customization No
  • Weight 99 grams (3.49 ounces)

Features

  • Interfaces to Voltages up to ±1000VDC and Currents up to ±100mA
  • Software Configurable Input Type and Range
  • Software Configurable Filter
  • 3700Vrms Transformer Isolation
  • Supply Voltage of 24 to 60VDC/AC or 85 to 230VDC/AC
  • Alarm Relay Output
  • Mounts on Standard DIN Rail
  • -25°C to +55°C Operating Temperature
  • CE Compliant

Block Diagram

DSCP81 block diagram

Accessories

DSCX-557
Configuration Software View
DSCX-587
Module Interface Cable View
DSCX-787
PC Interface Cable View

Competitive Cross-Reference

  • No cross reference is available.
View Dataforth cross-reference data.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.

This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.

FAQ

I have a high-speed application that requires a module for converting current to voltage (4-20mA to 0-5V) and also from voltage to current (0-5V to 4-20mA). Due to the high-speed of the application it would be preferable if there was no internal filter. Does Dataforth have a module that could meet these requirements?
The DSCP63 DC Voltage/Current converter is a match for this application. This module provides a single channel of voltage or current input which is converted to a voltage or current output. Input/output range, filter, fault indication, square root function and other functions may be configured by dip-switch. Disabling the filter on this module will reduce response time from <74ms to <35ms. Other modules that have configurable filters include the following: DSCP55, DSCP61, DSCP62, DSCP64, DSCP65, and DSCP81.
Due to resource constraints on my computer, I'm unable to open the three dimensional CAD models provided on your website. Does Dataforth provide two demensional CAD models for download as well?
Two dimensional CAD models can be generated upon customer request. Please contact Customer Service for assistance.
Can I create a custom 4-20mA output curve from a linear 4-20mA input signal with the DSCP81?
Yes, custom non-linear output curves can be configured from a linear input with the DSCP81 using the DSCX-557 software. The DSCX-787 and DSCX-587 cables are required to connect to the PC to configure the module.
How does the load resistance of a module affect the noise at the output?
Noise at the output of a module is independent of load resistance.
Can Dataforth provide calibration reports for modules I purchased?
Yes we can provide calibration reports for the modules that you purchased. You can either a) visit https://www.dataforth.com/TestDataReport.aspx to search for Test Report Datasheets by Serial Number or b) you can send us a list of model numbers and their serial numbers to support@dataforth.com