MAQ20-ISOV3
Isolated Analog Voltage Input Module; ±20V
MAQ20-ISOV3
Isolated Analog Voltage Input Module; ±20V
MAQ20-ISOV3 added to cart.
Description
The MAQ20-ISOMV and MAQ20-ISOV voltage input modules and MAQ20-ISOI current input module offer 8 isolated input channels with multiple signal ranges and high resolution conversion for precise measurement of a wide range of analog voltage and current signals. All channels are individually configurable for range, alarm limits, averaging, and high-speed burst scan to match the most demanding applications. High, Low, High-High and Low-Low alarms provide essential monitoring and warning functions to ensure optimum process flow and failsafe applications. Signal bandwidth is 1kHz for voltage input and 1kHz for current input. The burst scan mode allows up to 5kS/s per channel to be captured simultaneously. Field I/O connections are made through a pluggable terminal block with four positions provided for the termination of wiring shields.Input-to-bus isolation is a robust 1500Vrms and each individual channel is protected up to 240Vrms continuous overload in case of inadvertent wiring errors. In addition, the MAQ20-ISOMV, -ISOV, and -ISOI modules have 300Vrms continuous channel-to-channel isolation. Overloaded channels do not adversely affect other channels in the module, thereby preserving data integrity.
Signal ranges for the voltage input modules are from ±100mV to ±10V, and for the current input module, 0 to 20mA.
All MAQ20 modules are designed for installation in Class I, Division 2 hazardous locations and have a high level of immunity to environmental noise commonly present in heavy industrial environments.
Features
- 8 Isolated Input Channels with Multiple Ranges and High Resolution Conversion
- Precise Measurement of Wide Range of Analog Voltage and Current Signals
- Channels Individually Configurable for Range, Alarm Limits, Averaging, and High-speed Burst Scan Mode
- 1500Vrms Input-to-Bus Isolation
- 300Vrms Channel-to-Channel Isolation
- Each Channel Protected up to 240Vrms Continuous Overload
- Overloaded Channels Do Not Adversely Affect Other Channels
- UL/cUL (Class I, Division 2, Groups A, B, C, D)
Block Diagram
Documents
CAD Model
MAQ20 Module & Accessory 3-D CAD Models
MAQ20 Module & Accessory 3-D CAD Models
Specifications
- Sensor Type Process Voltage
- Input Range 0 to +20V, ±20V (Default)
- Output Range
- Communication Via MAQ20-COM2 / -COM4
- Protocol Modbus TCP/IP or RTU
- Mechanical Format DIN rail mounting
- Isolation Voltage 1500Vrms
- Accuracy ±0.035% span
- Linearity ±0.02% span
- Cold Junction Compensation
- Supply Voltage / Current 270mA
- Input Voltage Protection 240Vrms max
- Output Voltage Protection
- Bandwidth, -3dB 1kHz Voltage Input
- Scan / Update Rate 500 Ch/s net, 65 Ch/s at 8-Ch Simultaneous
- NMR (60 Hz) Rejection 20dB/decade
- Output
- Excitation Voltage
- Dimensions 4.51” x 0.60” x 3.26”
- Operating Temperature –40°C to +85°C
- Weight 87 grams (3.07 ounces)
Accessories
MAQ20-5B26-0.3
IDC26-to-20 pos screw term Transition Cable, 0.3m (11.8”) long
View
MAQ20-5B26-0.6
IDC26-to-20 pos screw term Transition Cable, 0.6m (23.6”) long
View
MAQ20-5B26-01
IDC26-to-20 pos screw term Transition Cable, 1.0m (39.4”) long
View
MAQ20-XTB03
MAQ20 terminal block, 3 positions
View
MAQ20-XTB20
MAQ20 terminal block, 20 positions
View
Competitive Cross-Reference
- No cross reference is available.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.
This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.
This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.
FAQ
Was this content helpful?
Thank you for your feedback!