SCM5B45-22
Frequency Input Module
SCM5B45-22
Frequency Input Module
Product Availability:
- Usually stock to 3-5 weeks. Contact Customer Service for current lead times.
SCM5B45-22 added to cart.
Description
Each SCM5B45 frequency input module provides a single channel of frequency input which is isolated and converted to a high-level analog voltage output. This voltage output is logic switch controlled, which allows these modules to share a common analog bus without the requirement of external multiplexers.The frequency input signal can be a TTL level signal or a zero-crossing signal. Terminal 3 on the field-side terminal block is the "common" or ground connection for input signals. A TTL signal is connected from terminal 2 to terminal 3, while a zero-crossing signal is connected from terminal 4 to terminal 3. Input circuitry for each of the signal types has hysteresis built in. An input signal must cross entirely through the hysteresis region in order to trigger the threshold comparator.
A 5.1V excitation is available for use with magnetic pick-up or contact-closure type sensors. The excitation is available on pin 1 and the excitation common is pin 3.
The SCM5B modules are designed with a completely isolated computer side circuit which can be floated to ±50V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the output switch. If desired, the output switch can be turned on continuously by simply connecting pin 22, the Read-Enable pin, to I/O Common, pin 19.
A special circuit in the input stage of the module provides protection against accidental connection of power-line voltages up to 240VAC.
Features
- Accepts Frequency Inputs of 0 to 100kHz
- Provides High-Level Voltage Outputs
- TTL Level Inputs
- 1500 Vrms Transformer Isolation
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240VAC Continuous
- ±0.05% Accuracy
- CSA Certified, FM Approved, CE and ATEX Compliant
- Mix and Match SCM5B Types on Backpanel
Block Diagram
Specifications
- Input Range 0 to 1 kHz
- Output Range 0 to +5 V
- Zero Crossing Hysterisis ±400mV
- Mechanical Format Modular plug-in-board
- Isolation Voltage 1500 Vrms
- Isolation Type Transformer 3-way
- Accuracy ±0.05% Span
- Supply Voltage +5VDC ±5%
- Input Voltage Withstand 240 Vrms
- Gain/Offset Adjust N/A
- External I-to-V Resistor N/A
- Output Control Enable/Disable
- Output Resistance 50 Ohms
- Dimensions 2.28 x 2.26 x 0.60 inches
- Interface 14 pin
- Customization yes
- Weight 62 grams (2.19 ounces)
Accessories
PWR-4505
Power supply, 5A, 5VDC, 85 to 264VAC Universal, DIN mount, Switching power supply
View
SCM5B-PROTO
SCM5B breadboard kit
View
SCM5BPT-1367
Pass Thru Module with Switch, Non-isolated, unity gain
View
SCMPB01
Non-multiplexed, 16 channel backpanel
View
SCMPB01-1
Non-multiplexed, 16 channel backpanel, no CJC
View
SCMPB01-2
Non-multiplexed, 16 channel backpanel with DIN rail mounting option
View
SCMPB01-3
Non-multiplexed, 16 channel backpanel, no CJC, with DIN rail mounting option
View
SCMPB02
Multiplexed, 16 channel backpanel
View
SCMPB02-1
Multiplexed, 16 channel backpanel, no CJC
View
SCMPB02-2
Multiplexed, 16 channel backpanel with DIN rail mounting option
View
SCMPB02-3
Multiplexed, 16 channel backpanel, no CJC, with DIN rail mounting option
View
SCMPB03
Single channel backpanel
View
SCMPB03-2
Single channel backpanel, DIN rail mount
View
SCMPB04
Dual channel backpanel
View
SCMPB04-1
Dual channel backpanel, no CJC
View
SCMPB04-2
Dual channel backpanel, DIN rail mount
View
SCMPB04-3
Dual channel backpanel, DIN rail mount, no CJC
View
SCMPB05
Non-multiplexed, 8 channel backpanel
View
SCMPB05-1
Non-multiplexed, 8 channel backpanel, no CJC
View
SCMPB05-2
Non-multiplexed, 8 channel backpanel with DIN rail mounting option
View
SCMPB05-3
Non-multiplexed, 8 channel backpanel, no CJC, with DIN rail mounting option
View
SCMPB06
Multiplexed, 8 channel backpanel
View
SCMPB06-1
Multiplexed, 8 channel backpanel, no CJC
View
SCMPB06-2
Multiplexed, 8 channel backpanel with DIN rail mounting option
View
SCMPB06-3
Multiplexed, 8 channel backpanel, no CJC, with DIN rail mounting option
View
SCMPB07
Non-multiplexed, 8 channel backpanel
View
SCMPB07-1
Non-multiplexed, 8 channel backpanel, no CJC
View
SCMPB07-2
Non-multiplexed, 8 channel backpanel with DIN rail mounting option
View
SCMPB07-3
Non-multiplexed, 8 channel backpanel, no CJC, with DIN rail mounting option
View
SCMXBE
DIN rail base element without snap foot
View
SCMXBEFE
DIN rail base element with snap foot
View
SCMXCA004-01
System interface cable for both analog backpanels, 1 meter length
View
SCMXCA004-02
System interface cable for both analog backpanels, 2 meter length
View
SCMXCJC
Encapsulated cold junction compensation circuit
View
SCMXDB37F25BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXDB37F27BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXDB37F28BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXDB37F5BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXDB37F7BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXDB37F8BP00
Third Party DAQ Front-Ending Adapter for Dataforth Backpanels
View
SCMXEV
Single channel SCM5B evaluation board
View
SCMXFS-003
Package of 10, 4A fuses
View
SCMXIF
Ribbon cable to screw terminal interface board
View
SCMXIF-DIN
Ribbon cable to screw terminal interface board, DIN mount
View
SCMXJP-003
Package of 10 jumpers
View
SCMXPRE-001
Power supply, 1A, 5VDC, 220VAC European
View
SCMXPRE-003
Power supply, 3A, 5VDC, 220VAC European
View
SCMXPRT-001
Power supply, 1A, 5VDC, 120VAC U.S.
View
SCMXPRT-003
Power supply, 3A, 5VDC, 120VAC U.S.
View
SCMXR1
Precision 20 Ohm resistor for SCM5B32 and SCM5B42
View
SCMXRAIL1-1.0
DIN EN 50022-35 x 7.5 (slotted steel), 1 meter length
View
SCMXRAIL1-2.0
DIN EN 50022-35 x 7.5 (slotted steel), 2 meter length
View
SCMXRAIL2-01
DIN EN 50035-G32 (slotted steel), 1 meter length
View
SCMXRAIL2-02
DIN EN 50035-G32 (slotted steel), 2 meter length
View
SCMXRAIL3-01
DIN EN 50022-35 x 15 (slotted steel), 1 meter length
View
SCMXRAIL3-02
DIN EN 50022-35 x 15 (slotted steel), 2 meter length
View
SCMXRK-002
19 inch metal rack for mounting analog backpanels
View
SCMXSE
DIN rail side element
View
SCMXVS
DIN rail connection pins
View
Competitive Cross-Reference
- The SCM5B45-22 equals the Analog Devices NOT AVAILABLE. For specific performance comparison, please review both datasheets.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.
This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.
This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.
FAQ
Was this content helpful?
Thank you for your feedback!