DSCL23-02

4-20mA Isolator with DC Supply - DIN or Panel Mount

DSCL23-02
4-20mA Isolator with DC Supply - DIN or Panel Mount

Product Availability:
  • Usually stock to 2-3 weeks.

Description

Each DSCL23 loop powered isolator provides 1 or 2 channels of analog signal protection by electrically isolating its input from output for any DC process signal in the range 4-20mA. The DSCL23 feeds isolated DC power to the field transmitter and returns a fully isolated 4-20mA analog signal.

The input signal is chopped by a proprietary DC chopper circuit, isolation is provided by transformer coupling, a proprietary technique is used to suppress transmission of common mode spikes or surges, and the output signal from the secondary of the transformer is reconstructed to the original input signal.

Specifications

  • Input Range 4 to 20 mA
  • Output Range 4 to 20 mA
  • Mechanical Format DIN rail,Panel Mount
  • Internal Power Supply 21.3VDC at 20mA load
  • Isolation Voltage 2300 Vrms
  • Isolation Type Transformer 3-way
  • Accuracy ±0.1% Span Typical
  • Supply Voltage 12 to 30 Vdc (+24V Nom)
  • Input Voltage Withstand
  • Gain/Offset Adjust N/A
  • Module Bandwidth 200 Hz
  • NMR (60 Hz) Rejection 20dB / decade above 200Hz
  • External I-to-V Resistor N/A
  • Output Control Continuous
  • Output Resistance
  • Dimensions 5.77 x 4.72 x 0.69 inches
  • Interface Miniature screw terminals
  • Customization no
  • Load Resistance N/A
  • Weight 171 grams (6.03 ounces)

Features

  • Feeds DC Power to 4 to 20mA Transmitter, Isolates Loop
  • Simplified Wiring for Quick Install and Signal Protection
  • DIN Rail or Panel Mountable
  • Narrow DIN Package, Mounts up to 27 Devices into a 19" Rack Space
  • No Recalibration or Maintenance Required
  • 2300Vrms Transformer Isolation
  • Prevents Ground-Loop Problems
  • Prevents the Transfer of Interference Voltages and Currents
  • High Accuracy Over Full Span
  • CE Compliant

Block Diagram

DSCL23 block diagram

Accessories

PWR-PS5R120W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 5.0 A Out View
PWR-PS5R15W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 0.65 A Out View
PWR-PS5R30W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 1.3 A Out View
PWR-PS5R60W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 2.5 A Out View
PWR-PS5R7W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 0.3 A Out View
SCMXRAIL1-1.0
DIN EN 50022-35 x 7.5 (slotted steel), 1 meter length View
SCMXRAIL1-2.0
DIN EN 50022-35 x 7.5 (slotted steel), 2 meter length View
SCMXRAIL2-01
DIN EN 50035-G32 (slotted steel), 1 meter length View
SCMXRAIL2-02
DIN EN 50035-G32 (slotted steel), 2 meter length View
SCMXRAIL3-01
DIN EN 50022-35 x 15 (slotted steel), 1 meter length View
SCMXRAIL3-02
DIN EN 50022-35 x 15 (slotted steel), 2 meter length View

Competitive Cross-Reference

  • No cross reference is available.
View Dataforth cross-reference data.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.

This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.

FAQ

Due to resource constraints on my computer, I'm unable to open the three dimensional CAD models provided on your website. Does Dataforth provide two demensional CAD models for download as well?
Two dimensional CAD models can be generated upon customer request. Please contact Customer Service for assistance.
How does the load resistance of a module affect the noise at the output?
Noise at the output of a module is independent of load resistance.
Can Dataforth provide calibration reports for modules I purchased?
Yes we can provide calibration reports for the modules that you purchased. You can either a) visit https://www.dataforth.com/TestDataReport.aspx to search for Test Report Datasheets by Serial Number or b) you can send us a list of model numbers and their serial numbers to support@dataforth.com
Why do I see a -10V shift when I change to a DSCL23 from a DSCA42-01C or similar?
The DSCA42-01C internal electronics is powered by an overall power supply and then the module output circuitry provides the output current whose return side (or negative side) is connected internally to the power supply common. This causes the output signal to be positive with respect to the common.

Whereas, the DSCL23 is loop-powered through its output terminals. That puts the 4-20mA receiver (the load) in series with the power supply. So when you measure the voltage from the power supply common (- terminal) to the other side of the load you will see a negative signal. The module could be made usable if the power supply has a fully floating output and you can make terminal 1 (the return current terminal) the common and measure the positive signal across the load from the power supply (-) to terminal 1 (the return current terminal), the common.

A better match for your application is the DSCA42-01C. Its internal electronics is powered by an overall power supply and then the module output circuitry provides the output current whose return side (or negative side) can be connected to the power supply common. This causes the output signal to be positive with respect to the common.

Keywords/Phrases: 4-20mA isolator with loop power, 2-wire transmitter interface signal conditioner with loop power
Does Dataforth have a 4-channel 4-20mA isolator?
No. However, Dataforth does have two and three-channel 4-20mA isolators as shown in the following table.

Model Description
DSCL22-11 2-channel 4-20mA isolator
DSCL22-21 3-channel 4-20mA isolator
DSCL23-02 2-channel 4-20mA Isolator with DC Supply for 2-wire transmitter
DSCL24-11 2-channel 4-20mA isolator

Keywords/Phrases: 4-20mA isolator, 4-channel 4-20mA isolator, 4-channel 4-20mA DIN mount isolator

Was this content helpful?
Thank you for your feedback!
Menu
Top