DSCA45-08C

Frequency Input Signal Conditioner

DSCA45-08C
Frequency Input Signal Conditioner

Product Availability:
  • Usually stock to 3-5 weeks. Contact Customer Service for current lead times.

Description

Each DSCA45 frequency input module provides a single channel of frequency input which is isolated and converted to a standard analog voltage or current output.

The frequency input signal can be a TTL level or zero-crossing signal. Terminal 7 (-IN) on the field-side terminal block is the "common" or ground connection for input signals. A TTL signal is connected from terminal 6 (+IN) to terminal 7 (-IN), while a zero-crossing signal is connected from terminal 5 (+EXC) to terminal 7 (-IN). Input circuitry for each of the signal types has hysteresis built in. An input signal must cross entirely through the hysteresis region in order to trigger the threshold comparator.

A +5.1V excitation is available for use with magnetic pick-up or contact-closure type sensors. The excitation is available on terminal 8 (-EXC) with return at terminal 7 (-IN).

Module output is either voltage or current. For current output models a dedicated loop supply is provided at terminal 3 (+OUT) with loop return located at terminal 4 (-OUT). The system-side load may be either floating or grounded.

Special input circuits provide protection against accidental connection of powerline voltages up to 480VAC and against transient events as defined by ANSI/ IEEE C37.90.1. Protection circuits are also present on the signal output and power input terminals to guard against transient events and power reversal. Signal and power lines are secured to the module using screw terminals which are pluggable terminal blocks for ease of system assembly and reconfiguration.

DSCA45 modules have excellent stability over time and do not require recalibration, however, both zero and span settings are adjustable to accommodate situations where fine tuning is desired. The adjustments are made using potentiometers located under the front panel label and are non-interactive for ease of use.

Features

  • Accepts Frequency Inputs of 0 to 100kHz
  • Industry Standard Output of Either 0-10V, 0-20mA, or 4-20mA
  • ±0.05% Factory Calibrated Accuracy
  • Adjustable Zero (±5%) and Span (±5%)
  • 1500Vrms Transformer Isolation
  • Input Overload Protected to 240VAC Continuous
  • ANSI/IEEE C37.90.1 Transient Protection
  • Mounts on Standard DIN Rail
  • C-UL-US Listed
  • CE and ATEX Compliant

Block Diagram

Certifications

Specifications

  • Input Range 0 to 100 kHz
  • Output Range 4 to 20 mA
  • Zero Crossing Hysterisis 40mV
  • Mechanical Format DIN rail
  • Isolation Voltage 1500 Vrms
  • Isolation Type Transformer 3-way
  • Accuracy ±0.05% Span
  • Supply Voltage 19 to 29 Vdc (+24V Nom)
  • Input Voltage Withstand 240 Vrms
  • Gain/Offset Adjust ±5%
  • External I-to-V Resistor N/A
  • Output Control Always enabled
  • Output Resistance <1 Ohm
  • Dimensions 2.95 x 0.89 x 4.13 inches
  • Interface 8 Pos terminal block
  • Customization yes
  • Weight 99 grams (3.49 ounces)

Accessories

DSCAX-01
Connector Plug Labeled 1,2,3,4 View
DSCAX-02
Connector Plug Labeled 5,6,7,8 View
DSCX-BLANK
Blank Empty DIN Rail Case for Holding Position. DSCA or DSCT View
PWR-PS5R120W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 5.0 A Out View
PWR-PS5R15W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 0.65 A Out View
PWR-PS5R30W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 1.3 A Out View
PWR-PS5R60W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 2.5 A Out View
PWR-PS5R7W
Power Supply, DIN Rail Mount, 85-264 VAC 47-63 Hz In, 24 VDC 0.3 A Out View
SCMXRAIL1-1.0
DIN EN 50022-35 x 7.5 (slotted steel), 1 meter length View
SCMXRAIL1-2.0
DIN EN 50022-35 x 7.5 (slotted steel), 2 meter length View
SCMXRAIL2-01
DIN EN 50035-G32 (slotted steel), 1 meter length View
SCMXRAIL2-02
DIN EN 50035-G32 (slotted steel), 2 meter length View
SCMXRAIL3-01
DIN EN 50022-35 x 15 (slotted steel), 1 meter length View
SCMXRAIL3-02
DIN EN 50022-35 x 15 (slotted steel), 2 meter length View

Competitive Cross-Reference

  • No cross reference is available.
View Dataforth cross-reference data.
The information available through this competitive cross reference guide are based upon product catalog information obtained from a variety of sources. The competitive cross reference information is being provided to you free of charge for your use. While Dataforth Corp has used reasonable efforts to ensure data accuracy, Dataforth Corp does not guarantee that it is error-free, nor does Dataforth Corp make any other representation, warranty or guarantee that the information is accurate, correct, reliable or up-to-date. Dataforth Corp expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties of merchantability or fitness for a particular purpose.

This information is provided only as a convenience on an "as is" basis and Dataforth Corp. or its representatives or distributors are not responsible for any incorrect, inaccurate, or incomplete information. You are solely responsible for (1) selecting the appropriate Dataforth products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements.

FAQ